Sivacon 8PT Low Voltage Mai Cire MCC Sauyawa
Gabaɗaya Gabatarwa
Nau'in nau'in GPS1 shine na Siemens breakers na ƙananan ƙarfin rarraba wutar lantarki, wanda ke da fasahar keɓaɓɓiyar da'ira, fasahar tsayayyen dutse, fasahar ƙira mai cirewa da fasahar toshewa.Yana da aminci, abin dogara, sassauƙa, ana amfani da shi sosai a cikin masana'antar gini da filayen fasahar masana'antu.
Samfurin yana da halaye masu zuwa:
● Ƙananan kayan aikin rarraba wutar lantarki nau'in-gwajin (TTA);
● Mos ɗin bas ɗin da aka haɗa a kwance an shirya shi a saman kayan sauyawa;
● 3-Pole da 4-pole basbar tsarin rated halin yanzu har zuwa 7400A;
● Ƙimar ƙwaƙƙwarar tsayin daka na yanzu 1pk zai iya kaiwa 375kA;
● Babban zurfin zurfin sashin na'urar, wanda ya dace da nau'ikan shigarwa;
● Za'a iya raba sashin na'ura zuwa raka'a daban-daban kamar tsarin modulus;
● Ana iya shigar da kayan aiki a gefe ɗaya, kuma za'a iya dawowa baya shigarwa;
● Layi mai shigowa na iya zama daga sama ko daga ƙasa;
● Ana iya haɗa igiyoyi masu fita daga gaba ko bayan majalisar.
GPS1 ƙananan kayan wutan lantarki mai ɗauke da jimillar ƙira huɗu: Mai karya ƙira, ƙayyadaddun ƙira, ƙirar filogi da ƙira mai cirewa.
Breaker zane don yin aiki, za a iya raba matakin bas na yanzu zuwa 3200A, 4000A, 7400A, ɗakin daɗaɗɗen kebul a gefe ko baya, za'a iya canja wurin mai watsawa daga matsayi na haɗi, matsayi na gwaji zuwa matsayi mai mahimmanci.Mai karyawa kawai a keɓe wuri, ƙofar za a iya buɗewa, wannan yana tabbatar da iyakar amincin mutum.
Kafaffen-Mount-Mount tsarin tsarin mulki, wanda ke sa da'irori feeder a cikin majalisar zai iya zama kowane hade.An shigar da kafaffen majalisar ko saka nau'in gyare-gyaren shari'ar da'ira (MCCB), nau'in fuse nau'in disconnectors, ko masu cire haɗin nau'in tsiri tare da fius, matsakaicin adadin busbar ɗin sa wanda aka ƙididdige shi shine 1400A;Ajin kariya na rarraba busbar na tsiri fiusi hukuma shine IP20B, ta amfani da tube 3NJ6 fuse switch, na'urar za a iya maye gurbinsa ba tare da ikon saukar da duka majalisar ba.Power factor diyyar majalisar ministocin yana da shake da mara shake irin.
Kowane zane mai cirewa na aljihu yana da haɗin haɗin gwiwa, matsayin gwaji da keɓewar matsayi.Zane sama da 125A yana da hanyar da za ta iya shawo kan aljihun tebur da ke ci gaba da aiwatar da gogayya.Madaidaicin aljihun aljihun 630A, aljihun aljihun teburi shine 100,150,200,300,400,500,600,700mm.
An ƙera nau'in plug-in don shigar da na'ura mai mahimmanci a kan slats, toshe cikin babban kewayawa da filogi mai taimako tare da slat, babban tashar kebul na kewayawa don ɗaukar kafaffen wayoyi kai tsaye da aka haɗa zuwa na'urorin fitarwa.Wannan zane ya fi farashin tattalin arziki.
Domin daidaita buƙatun injiniya bisa ga daidaitaccen ƙirar BS, duk tsarin bas ɗin da aka tsara an aiwatar da 3S wanda aka ƙididdige ɗan gajeren lokaci don jure gwajin yanzu.
Tsarin Firam da Yawa
ɓangarorin ɗaukar nauyi na kwarangwal canza majalisar, wanda aka yi da bayanan martaba na ƙarfe da ke haɗa juna, tsarin kwarangwal na GPS1 daidai da daidaito.Akwai nau'ikan tsari guda biyu, wato haɗin dunƙule ko walda.
● Bayanan martaba yana da 25mm ramin nisa modules don saduwa da bukatun kari daban-daban
● Juyawa mai riƙon ruwa na iya dogaro da dogaro ya hana barin billa kofa da gangan ko bisa kuskure
● Rufin da aka sanye da na'urorin taimako na matsa lamba
Yadi
Farantin rufi
An dunƙule farantin rufi a kan firam ɗin, ana iya ɗaga rufin ba tare da tarwatsa kayan sauya kayan aiki ba, rufin aji na nau'in kariya na IPX1 ko IPX2 zai isar da shi azaman kayan haɗi.
Farantin gindi
Domin rufe SPS1 daga kasa, za a iya screwed zuwa Framing jam'i na karfe faranti, za ka iya naushi ramukan a kasa domin threading da igiyoyi.Don mafi girman matakin buƙatun kariya, Bayan ɗora farantin ƙasa a wurin zai iya amfani da abin rufewa na yau da kullun don toshewa.
Rear plate da Side bango
GPS1switchgear baya da ɓangarorin an yi su ne da farantin karfe ba chamfered da sukurori a haɗe zuwa tsarin goyan baya.
Farantin rabo
Dangane da rabuwar ciki na nau'ikan nau'ikan daban-daban, don shigarwa na GPS1 switchgear a jere, an karɓi farantin ɓangaren don ware tsakanin nau'in rabon.Ana ɗora Spacer a waje na firam ɗin hagu.
Cikakkun kwarangwal
Kafaffen Nau'in Bayani da Fasaloli
KASHE1 yana amfani da kafaffen hukuma mai ciyar da fasahar hawa, za'a iya shigar da gyare-gyaren yanayin da'ira (MCCB), masu cire haɗin fuse.
KASHE1 ƙayyadaddun da'irori masu fita da aka shigar ta hanyar abun da ke tattare da sashin na'ura na zamani kuma yana cikin bayan sashin kebul.
Gaban Switchgear shine kofa ko faranti.
KASHE2 majalisar rarraba ciyarwar da'irori masu fita yana amfani da ƙayyadaddun fasahar dutsen da za'a iya shigar da na'ura mai juzu'i (MCCB), masu cire haɗin fuse.
KASHE2 wutar lantarki na kebul feeder circuits an ɗora akan farantin mai hawa kuma an haɗa shi zuwa bas ɗin rarraba a tsaye a gefen mai shigowa.
Gaban Switchgear yana da ƙofofin ɗaki daban, ɗakunan haɗin kebul suna gaba kuma.
KASHE3 ciyarwar da aka kafa kafaffen kafaffen majalisar shigarwa an haɗa shi da sashin na'ura na zamani da kebul na USB wanda ke bayan majalisar ministoci.
KASHE3 na USB feeder circuits ana ɗora wutar lantarki akan farantin mai hawa kuma an haɗa shi zuwa bas ɗin rarraba a tsaye na gefen mai shigowa.
Gaban Switchgear yana da ƙofofin ɗaki daban.
KASHE 4 masu fita da'irori kafaffen shigarwa yana ƙunshe da sashin na'ura na zamani da kebul na kebul wanda yake a gaban ɓangaren majalisar.
KASHE 4 na USB feeder circuits ana ɗora wutar lantarki akan farantin mai hawa kuma an haɗa shi zuwa bas ɗin rarraba a tsaye a gefen mai shigowa.
Gaban Switchgear yana da ƙofofin ɗaki daban.
Nau'in Tsara-Fita
An sanye shi da injin lantarki da da'irori na ciyarwa na switchgear mai cirewa a cikin aminci da sassauƙan yanayin samar da aiki mai dacewa, ta hanyar ƙira mai cirewa, ba da damar sauyawa da sauƙi da sauƙi da daidaitawa, wanda ke nufin cewa yayin aikin, ana iya ƙara ɗakunan module kuma maye gurbin ko canzawa.
Siffofin
Babban da'ira tare da shinge mai motsi (watsewa a gefen mai shigowa da gefen fitarwa) da da'irori masu taimako (har zuwa 40-pin + 1 mai haɗin bas) na tsarin sadarwar.Tsarin kariyar rashin amfani yana hana motsi idan ana hulɗa da kaya.A cikin matsayi na gwaji, ana iya gano aikin dangi na raka'o'in da za a iya cirewa a cikin kuskuren nauyin kaya (matsayin sanyi).A cikin wannan matsayi, muna buƙatar ciyar da wutar lantarki mai sarrafawa ta hanyar lambobin sadarwa.Matsayin kariya akan matsayin gwaji da keɓantaccen matsayi ya kai IP30.