MNS Low Voltage Mai Cire MCC Sauyawa
GPM1 Maɓallin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarfafawa
GPM1 low-voltage janye switchgear shine fasahar ABB ta ci-gaba mai ƙarancin wutar lantarki.
GPM1 ne na zamani, Multi-aikin low irin ƙarfin lantarki rarraba majalisar ministoci a cikin duniya fiye da shekaru 40 na aiki tarihi, yadu amfani a karafa, man fetur, sinadaran, masana'antu da ma'adinai Enterprises, da kuma kayayyakin more rayuwa ga duk lokatai da bukatar high aminci low-voltage tsarin. , rarraba wutar lantarki da tsarin sarrafa motoci.
Wannan na'urar ita ce ma'aunin ma'auni na ma'auni wanda aka haɗa na'ura mai ƙarancin wuta na AC 50-60Hz, ƙimar ƙarfin aiki 600V da tsarin wutar lantarki na ƙasa don samar da wutar lantarki, watsawa, rarrabawa, canjin wuta da sarrafa amfani da wutar lantarki na kayan aikin da aka yi amfani da su.
GPM1 majalisar yana da sassauƙa sosai, ana iya shigar dashi a cikin nau'ikan ƙira da ƙayyadaddun abubuwan haɗin gwiwa gwargwadon buƙatu na musamman da lokuta daban-daban.A madadin, zaku iya dogara da nau'ikan nau'ikan kayan abinci na lantarki waɗanda aka ɗora a cikin ginshiƙi ɗaya ko hukuma ɗaya kamar yadda za'a iya haɗawa da da'irori masu sarrafa motoci tare.
GPM1 low-voltage janye switchgear shine cikakken kewayon ƙarancin wutar lantarki, tsarin ƙarancin wutar lantarki ya dace da duk 5000A na yanzu ko ƙasa da haka.
Drawers: 8E/4, 8E/2, 8E, 12E, 16E, 20E, 24E don tsarin majalisar da daban-daban zažužžukan.
Majalisar Aiki na Sashe
Nau'in nau'in nau'in nau'in nau'in basbar mai aiki da yawa yana haɗuwa tsakanin babban ɗakin da'irar da ɗakin lantarki.
Anyi ta hanyar kayan injiniya mai zafi da siffa.Yana da fasali na rigakafin wuta, mai ƙarfi, mai ƙarfi da ƙarfi mai ƙarfi da kuma ayyukan gujewa yadda ya kamata a guje wa haɗarin canji da ke haifar da gajeriyar kewayawa tsakanin arc da babban da'irar tashe ta hanyar rashin aiki.
Matsakaicin ƙarfin ƙarfinsa shine 380V (660V), kuma ƙimar wutar lantarki mafi girma shine 176KA, kuma ƙimar ɗan gajeren lokacin wutar lantarki yanzu shine 50kA ~ 80kA (1s).Farantin tashar busbar mai aiki da yawa (5GP 742 001) an haɗa shi da ƙarshen tsakiyar 9, iyakar tashoshi 2, tsiri na gasket na roba da kushin.Yana kuma iya gane mix shigarwa na PC hukuma da MCC hukuma.Idan maye gurbin babban tashar tashoshi tare da farantin raba, za a karbe shi a cikin nisa 600 MCC na baya mai fita mai cirewa.
Wannan samfuran da aka yi ta kayan aiki masu ƙarfi sosai kuma galibi ana amfani da su a gyara 50mm × 30mm × 5mm L nau'in babban kewayawa a tsaye.