ACB da MCCB
Takaitawa
GPU1/2/3 Series mai kaifin duniya mai watsewar iska an ƙera samfuran da mu, ƙimar ƙarfin lantarki na AC 50/60Hz, 480V(690V), 200A ~ 6300A na yanzu, galibi ana amfani da shi don rarraba wutar lantarki da da'irori don rarraba wutar lantarki. cibiyar sadarwa, hana samar da wutar lantarki da lalacewar kayan aikin lantarki daga kuskuren wuce kima, gajeren lokaci, kuskuren ƙasa, da dai sauransu .. Yana da babban kariyar zaɓi mai mahimmanci kuma yana inganta amincin samar da wutar lantarki.Breaker kuma yana da aikin keɓewa, yana dacewa da daidaitattun GB 14048.2, IEC 60947-2
Siffofin
1. Karamin tsari
2. Babu tazarar walƙiya Babban aminci
3. Babban ƙarfin On-Off
4. Nau'in Smart nau'in kariya na balaguro na yau da kullun, tare da hanyar sadarwar sadarwa, Za'a iya sarrafa ta ta gungu na kwamfuta, ayyukan nesa da aka gane.
5. Nuni aikin ammeter, voltmeter
6. Sama da ƙasa mai shigowa ba zai shafi aikin samfur ba
Samfura
GPU3 | Universal air circuit breaker |
1600 | Garkuwar firam na yanzu |
4 | 3-3-lokaci ba alama 4 4-Mataki |
Nau'in 3M mai kula da hankali | Mai sarrafa wayo Nau'in 2M: Nunin bututu na dijital, daidaita maɓalli, sashe na 3 tare da aikin kare kuskuren ƙasa Nau'in 3M: Nunin LCD, Maɓallin daidaitawa, Sashe na 3 tare da aikin kare kuskuren ƙasa Nau'in 3H: nuni na LCD, daidaita maballin kuma don sadarwa, sashe 3 tare da earthing kuskure aikin kariya. |
Hanyar hawa | Nau'in zana Kafaffen nau'in |
Hanyar haɗi | A kwance wayoyi a tsaye Wurin lantarki na gaba |
Zaɓin kayan haɗi | Ƙarƙashin ƙarfin wutar lantarki Makullin injina: saiti 2 ko saiti 3 a cikin lefa na tsaye wanda aka kulle 2 saitin mai karya a kwance ko a tsaye wanda ke kulle ta hanyar kebul na karfe Matsayin “Buɗe” (kulle maɓalli) Zane-fita 3 matsayi canza Haɗin waje na N Phase Transformer |
A cikin = 630 | Ƙididdigar halin yanzu (A) |
Lura:
1. Smart mai kula shine nau'in M;Maɓallin taimako: Lambobin ƙungiyoyi 4, Hanyar haɗin kai tana cikin kwance.
2. Mai sarrafa wayo, na'urar sakin shunt, na'urar lantarki na kusa, injin tukin mota da ma'aunin wutar lantarki za a ƙayyade ƙimar ƙarfin lantarki lokacin yin oda.
Teburin Zaɓin Fasaha
Nau'in | Ƙimar wutar lantarki mai aiki Ue(V) | Ƙimar insulating Wutar lantarki Ui(V) | Ƙimar ƙwaƙƙwarar ƙarfin ƙarfin jurewar wutar lantarki Uimp (V) | Tsarin garkuwa halin yanzu Inm (A) | Ƙididdigar halin yanzu Inm (A) | Lambar mataki |
GPU1-1250 | AC400 AC690 | AC690, AC1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3, 4 |
GPU1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
GPU1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
GPU1-6300 | 6300 | 4000, 5000, 6300 |
Ƙarfin ƙetare gajere | Ƙididdigar ɗan gajeren lokaci jure wa Icw (kA)/1s | Ayyukan aiki | |||||
Icu (kA) da aka ƙididdige iyawar ɗan gajeren kewayawa | Ics (kA) da aka ƙididdige iyawar gajeriyar kewayawa | Rayuwar injina (lokutai) | Rayuwar wutar lantarki (Lokaci) | ||||
400V | 690V | 400V | 690V | 400V | 690V | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000(5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
GPM11 Molded Case Breaker
GPM11Z Smart Molded Case Mai karyawa
Bayani na GPM11/GPM11Z
GPM11 jerin gyare-gyaren yanayin yanayin da'ira ya dace da AC 50/60Hz rated aiki ƙarfin lantarki 400V/630V, rated halin yanzu har zuwa 800A na ikon rarraba cibiyar sadarwa don rarraba wutar lantarki da kariyar da'irori, samar da wutar lantarki da lantarki kayan aiki a kan obalodi, karkashin-voltage da kuma gajerun hatsarori, yana inganta amincin samar da wutar lantarki a ƙarƙashin yanayin amfani na yau da kullun waɗanda ba sau da yawa farawa kamar jujjuyawar layi da motsi ba.Kuma tare da aikin warewa kuma.Ya dace da daidaitattun GB/T 14048.2 da IEC 60947-2.
Samfura
Saukewa: GPM11GPM11Z | Molded Case Circuit BreakerSmart Molded Case Circuit breaker |
100 | Garkuwar firam na yanzu |
H | Ƙarfin karya gajeriyar kewayawa:N: Nau'in al'ada S: Nau'in daidaitaccen nau'in: Nau'in mai ƙarfi |
P | Hanyar aiki: Motar aiki: Mai sarrafa kayan aiki: Aiki na ZDirect (babu lambar) |
2 | Siffar kariya Zaɓi: Kariyar rarrabawa: babu kariyar moto: 2 |
4 | Mataki na 2 : matakai biyu 3: uku4 : kashi hudu |
208 | Hanyar tafiya da lambar kayan haɗi na ciki |
A cikin = 100 | Ƙididdigar halin yanzu (A) |
B | 4 Phase breaker N Phase suna da nau'ikan nau'ikan nau'ikan 4 daban-daban masu alama kamar A, B, C, DA: N lokaci ba zai shigar da tripper na yanzu ba, kuma N yana haɗa koyaushe, ba'a sarrafa shi da sauran nau'ikan 3.B: N Phase ba shigar da tripper na yanzu ba, da N. lokaci ba a sarrafa shi tare da wasu matakai 3.C: N lokaci shigar tripper na yanzu, da kuma N lokaci aiki tare da wasu matakai 3.D: N lokaci an shigar da tripper na yanzu, kuma N lokaci yana haɗa koyaushe, Ba a sarrafa shi tare da wasu matakai 3. |
Q | Hanyar Waya: Gaban farantin waya: QRear na farantin waya: HNau'in plug-in waya: R |
Lura: 1. Hanyar hanyar waya: baya na farantin karfe (400, 630's 4P ba tare da shi ba);na'ura mai ba da hanya tsakanin hanyoyin sadarwa (4P ba tare da shi ba)
2. Ana shigar da kayan haɗi na ciki a gefen hagu na mai karya.
Teburin zaɓi na fasaha don GPM11Z MCCB
Nau'in | Ƙimar wutar lantarki mai aiki Ue(V) | Ƙimar insulating Wutar lantarki Ui(V) | Ƙimar kuzari jure ƙarfin lantarki Uimp (V) | Tsarin garkuwa halin yanzu Inm (A) | Ƙididdigar halin yanzu Inm (A) | Lambar mataki | Ƙarfin ƙetare gajere | Ƙididdigar ɗan gajeren lokaci jure halin yanzu Icw (kA) 1s | Ayyukan aiki | ||
Icu (kA) da aka ƙididdige iyawar ɗan gajeren kewayawa | Ics (kA) da aka ƙididdige iyawar gajeriyar kewayawa | Rayuwar injina (lokutai) | Rayuwar Wutar Lantarki (Lokaci) | ||||||||
Saukewa: GPM11Z-100 | AC400 | Saukewa: AC690 | AC8000 | 100 | 32, 100 | 3,4 | 65 | 50 | 1 | 20000 | 8000 |
Saukewa: GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | 20000 | 8000 | ||||
Saukewa: GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
Saukewa: GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Teburin zaɓi na fasaha don GPM11 MCCB
Nau'in | Ƙimar wutar lantarki mai aiki Ue | Ƙididdigar wutar lantarki Ui | Ƙimar ƙwaƙƙwarar ƙarfin ƙarfin juriya Uimp | Ajin firam wanda aka ƙididdige Inm A na yanzu | Ƙididdigar halin yanzu A (A) | Lambar mataki | Matsakaicin lambar iya karya gajeriyar kewayawa | An ƙididdige max gajere - iyawar karya kewaye | Ics (kA) da aka ƙididdige iyawar gajeriyar kewayawa | Nau'in na'urar tafiya | Ayyukan aiki (lokaci) | |
Rayuwa | Ba-Rayuwa | |||||||||||
Saukewa: GPM11-63 | 400, 690 | 800, 1000 | 8 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 3 | N | 10 | 5 | Zafin lantarki | 3000 | 7000 |
3,4 | S | 25 | 18 | Zafin lantarki | ||||||||
3,4 | H | 50 | 35 | Zafin lantarki | ||||||||
Saukewa: GPM11-100 | 100 | 16, 20, 25, 32, 40, 50, 63, 80, 100 | 3 | N | 35 | 25 | Zafin lantarki | 3000 | 7000 | |||
3,4 | S | 50 | 35 | Zafin lantarki | ||||||||
3,4 | H | 65 | 50 | Zafin lantarki | ||||||||
Saukewa: GPM11-160 | 160 | 100, 125, 140, 160 | 3 | N | 35 | 25 | Zafin lantarki | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Zafin lantarki | ||||||||
3,4 | H | 65 | 50 | Zafin lantarki | ||||||||
Saukewa: GPM11-225 | 225 | 100, 125, 140, 160, 180, 200, 225 | 3 | N | 35 | 25 | Zafin lantarki | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Zafin lantarki | ||||||||
3,4 | H | 65 | 50 | Zafin lantarki | ||||||||
Saukewa: GPM11-250 | 250 | 100, 125, 140, 160, 180, 200, 225, 250 | 3 | N | 35 | 25 | Zafin lantarki | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Zafin lantarki | ||||||||
3,4 | H | 65 | 50 | Zafin lantarki | ||||||||
Saukewa: GPM11-400 | 400 | 225, 250, 315, 350, 400 | 3 | N | 35 | 25 | Zafin lantarki | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Zafin lantarki | ||||||||
3,4 | H | 65 | 50 | Zafin lantarki | ||||||||
Saukewa: GPM11-630 | 630 | 400, 500, 630, 630, 700, 800 | 3 | N | 35 | 25 | Zafin lantarki | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Zafin lantarki | ||||||||
3,4 | H | 65 | 50 | Zafin lantarki | ||||||||
Saukewa: GPM11-800 | 800 | 630, 700, 800 | 3,4 | S | 50 | 35 | Zafin lantarki | 1000 | 4000 | |||
3,4 | H | 65 | 50 | Zafin lantarki |