Manuniya Da Mitar Makamashi
Nau'in Bayanin
Nau'in | Abu | Hanyar nunawa | Ƙarfi | Kulle guda ɗaya | Kulle lamba biyu | Saka | Kai | Girma | Girman yankan | Hoto | |
duba | tuntuɓar | duba | |||||||||
Nau'in gini | GPXN-Q | Latsa maɓalli | - | 96×48×88 | 91×44 | 3 | |||||
GPXN-T | Latsa maɓalli | 96×48×55 | 91×44 | 3 | |||||||
Swg. | GPXN1-Q | Haske | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN1-T | Haske | - | 96×48×55 | 91×44 | 1 | ||||||
GPXN4-Q | Latsa maɓalli | - | - | 144×48×104 | 138×44 | 4 | |||||
GPXN4-T | Latsa maɓalli | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN5-Q | Latsa maɓalli | - | - | 96×48×88 | 91×44 | 2 | |||||
GPXN5-T | Latsa maɓalli | - | 96×48×55 | 91×44 | 2 | ||||||
Insulator guda ɗaya mai Manuniya 2 | GPXN4-Q/M | Latsa maɓalli | - | - | 144×48×104 | 138×44 | 4 | ||||
GPXN4-T/M | Latsa maɓalli | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN4-T/Z | Latsa maɓalli | 144×48×104 | 138×44 | 4 | |||||||
Nau'i Na Musamman | GPXN1-Q/CS | Haske | - | - | - | 96×48×88 | 91×44 | ||||
GPXNP1-Q/W | Haske | - | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN-Q/LCS | Haske | - | - | 96×48×88 | 91×44 | 3 |
Alamar Wutar Lantarki da Ake Amfani da shi a Babban Sashin Ring
Ana amfani da alamar wutar lantarki tare da insulator don nuna yanayin wutar lantarki na kewayen wutar lantarki.
Ana amfani da ci gaba da mai gano wutar lantarki GPXN9-C tare da nuna alama don nuna yanayin wutar lantarki.Nisan ramin tashar duba wutar lantarki shine 14mm ko 19mm.
Ana amfani da kwatancen lokaci GPXN-C tare da nuna alama don nuna yanayin wutar lantarki na babban ƙarfin lantarki da kuma duba jerin kayan lantarki.
Duban wuta: Saka kwatancen lokaci a cikin ƙasa ko sauran tashoshi na kayan aiki mai ƙarfi.
Duba-lokaci: Saka kwatancen lokaci a cikin tashar duba wutar lantarki iri ɗaya na kayan aiki masu ƙarfin ƙarfin lantarki guda biyu, idan hasken LED yana da haske, yana nuna cewa lokacin gwaji yana da wutar lantarki.
Alamar Matsayi
Alamar matsayi na iya kwaikwayi matsayin aiki da yanayin na'urar sauya sheka kamar mai juyawa da na'urar da'ira a tsarin lantarki.Ana amfani da shi sosai akan kowane nau'in allon mimic na ɗakin kulawa na tsakiya da panel of switchgear a cikin tashar wutar lantarki, tashar wutar lantarki da tashar wuta.Wannan serial na matsayi Manuniya da high AMINCI, fadi da kewayon aiki irin ƙarfin lantarki da kuma tsawon rai.DC da AC suna samuwa don amfani.
Ma'aunin Fasaha
Ƙarfin wutar lantarki | DC / AC 98V ~ 242V |
Ƙarfin haske | 40 cd/㎡ |
Mitar wutar lantarki jure wa wutar lantarki | 2kV/1 min |
Juriya na rufi | ≥100MΩ |
Rashin wutar lantarki | ≤1W |
Yanayin aiki | -15 ℃ zuwa +50 ℃ |
Tsawon rayuwa | : shekaru 10 |
Ayyukan nuni | Ana nuna yanayin aiki tare da launi ja / kore da zane (A matsayin zaɓi na abokan ciniki) |
Girman fayyace: | 37.5×37.5×62(mm) |
Girman Yanke: | Φ25(mm) |
Samfura | Bayani |
GPWZ25-K/2 | Alamar Matsayi-Circuit-Breaker |
GPWZ25-E/1 | Alamar Matsayi- Canjawar Duniya |
GPWZ25-B/2 | Motar Kula da Matsayi |
GPWZ25-B/1 | Mai Nuna Matsayi-Cire haɗin |
GPWZ25-K/1 | Alamar matsayi-Masanya matsayi uku |
Matsayi Mai Nuna Allon GPAS-72
A GPAS-72 serial matsayi nuna allon rungumi dabi'ar LED a matsayin haske Madogararsa, tare da low makamashi amfani, high AMINCI, dogon sabis rayuwa, da dai sauransu Kuma shi za a iya amfani da kowane irin switchgears a matsayin matsayi nuna allon tare da daban-daban tsarin zane mafita.Tare da ayyuka da yawa na nuni-ƙara-ƙara, kulle-kulle, zafin jiki & kula da zafi, nunin matsayi na keken hannu, nunin matsayi mai watsewa, nunin matsayin canjin ƙasa, nunin kuzari da aka adana.Zaɓi ne mai kyau don maye gurbin gargajiya guda ɗaya mai nuna matsayi na jihar.
Ma'aunin Fasaha
Ƙarfin wutar lantarki | AC / DC 110V/220V |
Juriya mitar wuta | 2kV/min |
Yanayin aiki | -25 ℃ zuwa 55 ℃, ≤90% RH |
Analog nuna alama haske haske | > 40cd/m2 |
Rayuwar aiki | shekaru 10 |
Matsayin kariya | IP42 |
Girma | 199x146x63mm |
Girman yankan | 177x121mm |
Ma'auni na FasahaGpj-3100 Jerin Gajerun Kewayawa Da Alamun Laifin Duniya
GPJ-3100 jerin gajeren kewayawa da alamar kuskuren ƙasa an tsara su don gwaji da nuna gajeriyar da'ira da kuskuren ƙasa a ainihin lokacin.Ana amfani da shi don saka idanu kan kewayawa a cikin RMU, layin sama, layin rarraba wutar lantarki, injin nau'in akwatin da sauran wurare makamantan haka.Dangane da siginar ƙararrawa da aka nuna ta mai nuna alama, ma'aikata na iya ganowa da yanke wurin kuskure cikin sauri lokacin da gajeriyar da'ira ko lahani na ƙasa ke faruwa a cikin kewayawa, don haka tsarin zai iya dawo da samar da wutar lantarki don yankin mara lahani da sauri don adana lokaci da haɓaka aiki.
Bayanan Fasaha
1. Shortarancin kewayawa na yanzu: 100A zuwa 1000A jinkirin lokaci 40ms
2. Duniya mai ban tsoro halin yanzu: 20A,30A,40A,50A,60A±10% jinkirin lokaci 40ms
3. Yanayin zafi: -25 zuwa +70 ℃
4. Yanayin zafi: ≦95%
5. Tsawon gubar duniya: 4m
6. Gudanar da fiber na gani tsawon 3.5m
7. Samar da wutar lantarki: baturin lithium 3.6V / 2.45Ah
8. Lokacin sake saiti ta atomatik: 7s,2hrs,4hrs,8hrs
9. Relay na fitarwa: 120V AC 1A, 30V DC 2A
10.Main mai sarrafawa girma: 95x50x80mm
11.Yanke girman rami: 91x44 mm
12.Protection class : Main Controller : IP40, Sensor: IP65