12/24/40.5kV Rukunin Majalisar da Haɗin kai
Matsakaicin Tsari 5GP.320.010 Tsarin Shigarwa
(800mm nisa tsaka-tsaki mai sauyawa)
Rufe Majalisar 5GP.320.010 Jerin Shirye-shiryen
A'a. | Suna | Zane no. | Qty(pc/set) |
1 | Bakin tallafi na dama | 8GP.123.011 | 1 |
2 | Farantin haɗin dama | 5GP.235.011 | 1 |
3 | Alamar alama | 8GP.866.014 | 1 |
4 | Haguwar hagu | 5GP.235.010 | 1 |
5 | Bangaren tallafi na hagu | 8GP.123.010 | 1 |
6 | Haɗa walda | 5GP.174.016.1 (Na VD4) | 2 |
5GP.174.016.2 (Na GPVN) | |||
5GP.174.016.3 (Na VB2) | |||
7 | Ƙofar rufewa | 8GP.320.010 | 1 |
8 | Toshe tashe 8 | DK-8 | 8 |
9 | Farantin karfe | 8GP.123.013 | 3 |
A'a. | Suna | Zane no. | Qty(pc/set) |
10 | Haɗa walda | 5GP.174.017.1 (Na VD4, 40kA) | 2 |
5GP.174.017.2 (Na VD4, 31.5kA) | |||
5GP.174.017.3 (Na GPVN) | |||
5GP.174.017.4 (Na VB2) | |||
11 | Alamar alama | 8GP.866.012 | 1 |
12 | Alamar alama | 8GP.866.013 | 2 |
13 | Farantin karfe | 8GP.123.012 | 3 |
14 | Babban rufewa | 8GP.320.011 | 1 |
15 | sandar jagora | 8GP.234.011(Na VD4, GPVN) | 2 |
8GP.234.011.1 (Na VB2) | |||
16 | Hannun tsayawa | 8GP.210.011 | 2 |
Sauran ƙayyadaddun lissafin tsari na rufewa
Lambar | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
Fadin majalisar | mm 650 | 700mm | mm 840 | 900mm | 1000mm |
Ƙofar babba | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
Ƙofar ƙasa | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
Rufe Majalisar 5GP.320.011
(1000mm nisa tsaka-tsaki mai sauyawa)
Na'urar Kayan aikin Shutter 5GP.320.011 Jerin Shirye-shiryen
(1000mm nisa tsaka-tsaki mai sauyawa)
A'a. | Suna | Zane no. | Qty(pc/set) |
1 | Bakin tallafi na dama | 8GP.123.276 | 1 |
2 | Farantin haɗin dama | 5GP.235.012 | 1 |
3 | Alamar alama | 8GP.866.014 | 1 |
4 | Farantin haɗin hagu | 5GP.235.013 | 1 |
5 | Bangaren tallafi na hagu | 8GP.123.275 | 1 |
6 | Haɗin haɗin walda | 5GP.174.281 | 2 |
7 | Rufe ƙasa | 8GP.320.273 | 1 |
8 | Toshewar 10 | DK-10 | 8 |
A'a. | Suna | Zane no. | Qty(pc/set) |
9 | Farantin karfe | 8GP.123.278 | 3 |
10 | Haɗin walda na haɗin gwiwa | 5GP.174.282 | 2 |
11 | Alamar alama | 8GP.866.012 | 1 |
12 | Alamar alama | 8GP.866.013 | 2 |
13 | Farantin karfe | 8GP.123.277 | 3 |
14 | Babban rufewa | 8GP.320.274 | 1 |
15 | sandar jagora | 8GP.234.272 | 2 |
16 | Hannun tsayawa | 8GP.210.011 | 2 |
Sauran ƙayyadaddun lissafin tsari na rufewa
Lambar | 5GP.320.011.1 | 5GP.320.011/JY | 5GP.320.011.2 | 5GP.320.011.3 |
Fadin majalisar | 800mm | 1000mm (Insulating) | 1100mm | 1200mm |
Ƙofar babba | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
Ƙofar ƙasa | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Note: 5GP.320.275 ne don insulating shutter ta SMC farantin a tsakiya da kuma biyu karshen da karfe farantin, sauran shutter taron idan bukatar insulating ƙofar da fatan a saka.
Griver Canja wurin aiwatar da na'ura ta hanyar amfani da kayan aiki (don haɗin hannun hannu) 5gp.363.010.1 Majalisar
Umarnin Interlock Na'urar
An ƙara na'urar makullin maɓalli na baya tare da ƙofar baya wanda aka ƙirƙira bisa tushen asali 5GP.363.010 earthing sauya tsarin na'urar interlock na'urar.Wato bayan an rufe maɓallan ƙasa sannan a buɗe ƙofar baya (farantin hatimi), kullin asali na iya aiki da maɓalli na ƙasa, amma wannan kullin ya kasa.Dole ne ku fara rufe ƙofar baya (farantin hatimi) don yin aiki da maɓallin ƙasa.
Ka'idodin aiki na na'urar kullewa an canza lambar kullewa ta lamba 24 zuwa abin da aka nuna akan dama kuma an ƙara bazara bisa tushen 5GP .363.010.Lokacin da ƙofar baya (farantin hatimi) ta buɗe, hannun rigar kulle ya shiga cikin murabba'in rami na majalisar (girman da aka ba da shawarar 35X35), ba za a iya sarrafa canjin ƙasa ba.
Na'urar makullin aiki ta ƙasa (Don aikin tuƙin hannu)
5GP.363.010.1 lissafin tsari.
A'a. | Suna | Zane no. | Qty(pc/set) |
1 | Mai ɗauka | 8GP.263.011 | 1 |
2 | Bangaren | 8GP.192.010 | 1 |
3 | Bangaren | 8GP.192.011 | 1 |
4 | Axis hannun riga | 8GP.210.014.1 | 2 |
5 | Bangaren | 8GP.151.041 | 1 |
6 | Axis hannun riga | 8GP.211.061 | 1 |
7 | Bangaren | 8GP.151.039 | 1 |
8 | Axis hannun riga | 8GP.211.062 | 1 |
9 | M5 × 12 | GB70-85 | 1 |
10 | Bangaren | 8GP.151.042 | 1 |
11 | Bangaren | 8GP.151.043 | 1 |
12 | sandar aiki | 8GP.200.013.1 (Dogon 1432 don zurfin majalisar 1500) | 1 |
8GP.200.013.2 (Dogon 1590 don zurfin majalisar 1660) | 1 | ||
13 | Farantin tallafi | 8GP.161.058 | 1 |
8GP.161.058.1 (Don zaɓi) | 1 |
A'a. | Suna | Zane no. | Qty(pc/set) |
14 | Rufewa | 8GP.017.011.1 | 1 |
15 | Bangaren | 5GP.043.022 | 1 |
16 | Farantin tallafi | 8GP.161.059 | 1 |
17 | Slider | 8GP.143.010 | 2 |
18 | Axis hannun riga | 8GP.211.058 | 1 |
19 | Hannun tsayawa | 8GP.211.057 | 3 |
20 | Tushen tallafi | 8GP.043.019 | 1 |
21 | Rufe nuni | 8GP.866.010 | 1 |
22 | Haɗin sanda taro taro | 5GP.233.030.1 | 1 |
5GP.233.030.3 (Don zaɓi) | 1 | ||
23 | Buɗe nuni | 8GP.866.011 | 1 |
24 | Kulle hannun riga | 8GP.211.201 | 1 |
25 | Farantin toshe hakori | 8GP.151.044 | 1 |
26 | Axis hannun riga | 8GP.211.060 | 2 |
27 | Tag | 8GP.860.010 | 1 |
28 | Matsi matsi | 8GP.282.201 | 1 |
29 | Kulle hannun riga yana gyara Bolt | 8GP.920.002 | 1 |
Lura:
1. No. 1 ~ 12 duba shafi na baya.
2. No. 22 Haɗin sandar haɗin gwiwa, haɗin haɗin haɗin yana da girman guda biyu: Nisa na majalisar ministocin 60mm a kowa.Idan ana buƙatar nisan tsakiya 80mm don Allah a duba shafi na 17 umarnin haɗin hannu na haɗin gwiwa, kuma saka lokacin yin oda.
Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙi ahayd (Don Bevel Gear Drive Aiki) 5GP.577.1001
Ƙarshen na'ura mai aiki da wutar lantarki (Don aikin motsa jiki na bevel) 5GP.577.1001 jerin tsarawa
A'a. | Suna | Zane no. | Qty(pc/set) |
1 | Mai ɗauka | 8GP.263.011 | 1 |
2 | Farantin karfe | 8GP.151.084 | 2 |
3 | Axis hannun riga | 8GP.210.014.1 | 2 |
4 | Bangaren | 8GP.151.041 | 1 |
5 | Axis hannun riga | 8GP.210.014.2 | 1 |
6 | Farashin M5X12 | GB70-85 | 1 |
7 | Bangaren | 8GP.151.042 | 1 |
8 | Bangaren | 8GP.151.043 | 1 |
9 | Axis hannun riga | 8GP.210.014.3 | 1 |
A'a. | Suna | Zane no. | Qty(pc/set) |
10 | Hannun tsayawa | 8GP.210.322 | 1 |
11 | sandar aiki | 8GP.174.214 | 1 |
12 | Rufewa | 8GP.017.011.2 | 1 |
13 | Tushen tallafi | 5GP.043.022 | 1 |
14 | Slider | 8GP.143.010 | 2 |
15 | Farantin tallafi | 8GP.161.059 | 1 |
16 | Farantin tallafi | 8GP.161.058 | 1 |
17 | Farantin toshe hakori | 8GP.151.044 | 1 |
18 | Tag | 8GP.860.010 | 1 |
Lura: 1. Wannan tsarin yana buƙatar kulle tare da ƙofar ƙasa, da fatan za a saka lokacin yin oda.