12 17.5 24kV na cikin gida Vacuum Circuit Breakers, GPVN-E Series
Yanayin yanayi
Yanayin yanayi: -25 ℃ ~ + 45 ℃, kullum matsakaita: ≤35 ℃
Tsayi: 1000m (Standard);iya har zuwa 4500m don oda na musamman;
Dangantakar zafi: matsakaita kullum ≤95%, matsakaicin kowane wata ≤90%;
Ƙarfin girgizar ƙasa ≤8 digiri;
Abubuwan da ake amfani da su ya kamata su kasance masu kuɓuta daga abubuwan ƙonewa, fashewar abubuwa, lalata da girgiza mai tsanani.
Samfura
GPVN -12Kv/17.5kV na cikin gida AC Babban Wutar Wutar Lantarki na Wuta
Ƙididdiga na Fasaha
A'a. | Abu | Naúrar | Bayanai | ||||||
1 | Ƙarfin wutar lantarki | kV | 7.2 ~ 12 (15/17.5) | ||||||
2 | Ƙididdigar mita | Hz | 50/60 | ||||||
3 | Ƙididdigar halin yanzu | A | 630,1000,1250 | 1600 | 2000,2500,3150 | 4000 | |||
4 | An ƙididdige ɗan gajeren da'ira karya halin yanzu | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
5 | An ƙididdige gajeriyar da'ira yin halin yanzu | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
6 | Ƙididdigar ɗan gajeren lokaci jure halin yanzu | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
7 | Ƙimar kololuwar jure halin yanzu | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
8 | An ƙididdige ficewar fitar da halin yanzu | kA | 12.6 | 12.6 | 16 | 16 | 20 | ||
9 | Ƙididdigar ɓoyayyiyar ɓarnar ɓarna na ƙasa | kA | 17.4 | 21.7 | 27.4 | 27.4 | 34.7 | 34.7 | 43.5 |
10 | An ƙididdige ɗan gajeren kewayawa karya lokacin karyewar halin yanzu | Lokaci | 50 | 30 | 30 | 12 | |||
11 | An ƙididdige jerin ayyuka | O-0.3s-CO-180s-CO | O-180s-CO-180s-CO | ||||||
12 | Ƙididdigar karya halin yanzu na bankin capacitor guda ɗaya | A | 630 | ||||||
13 | Ƙididdigar karya halin yanzu na bankin capacitor na baya | A | 400 | ||||||
14 | 1 min.Mitar wutar lantarki jure wa wutar lantarki | kV | Matakin zuwa mataki/zuwa ƙasa: 42, a kan buɗaɗɗen lambobin sadarwa:48 | ||||||
15 | Wutar walƙiya tana jure wa wutar lantarki | kV | Matakin zuwa mataki/zuwa ƙasa: 75, a kan buɗaɗɗen lambobin sadarwa:85 | ||||||
16 | Rayuwar injina | Lokaci | 20000 | ||||||
17 | Lokacin rufewa | ms | ≤75 | ||||||
18 | Lokacin budewa | ms | ≤60 | ||||||
19 | Lokacin ajiyar wutar lantarki ƙarƙashin ƙimar ƙarfin lantarki | s | ≤10 |
Bayanan Bayani na GPVN-12E
GPVN-24□ Babban Wutar Wutar Lantarki na Cikin Gida Mai Breaker
Ƙayyadaddun Fasaha
A'a. | Abu | Naúrar | Bayanai | |||
1 | Ƙarfin wutar lantarki | kV | 24 | |||
2 | Ƙididdigar mita | Hz | 50/60 | |||
3 | Ƙididdigar halin yanzu | A | 630 1250 1600 2000 2500 3150 4000 | |||
4 | An ƙididdige ɗan gajeren da'ira karya halin yanzu | kA | 20 | 25 | 31.5 | 31.5 |
5 | An ƙididdige gajeriyar da'ira yin halin yanzu | kA | 50 | 63 | 80 | 80 |
6 | Ƙididdigar gajeren kewayawa jure halin yanzu(4s) | kA | 20 | 25 | 31.5 | 31.5 |
7 | Ƙimar kololuwar jure halin yanzu | kA | 50 | 63 | 80 | 80 |
8 | An ƙididdige fitar da matakin karya halin yanzu | kA |
|
| 12.6 | 12.6 |
9 | Ƙididdigar karya halin yanzu na kuskuren duniya wanda ba ya wuce lokaci | kA | 17.4 | 21.7 | 27.4 | 27.4 |
10 | An ƙididdige lokutan karya na gajeren zangon karya halin yanzu | Lokaci | 50 | |||
11 | An ƙididdige jerin aiki |
| O-0.3s-CO-180s-CO | |||
12 | Ƙididdigar karya halin yanzu na bankin capacitor guda ɗaya | A | 630 | |||
13 | Ƙididdigar karya halin yanzu na bankin capacitor na baya-da-baya | A | 400 | |||
14 | 1 min.Mitar wutar lantarki jure wa wutar lantarki | kV | 50 | |||
15 | Wutar walƙiya tana jure wa wutar lantarki | kV | 125 | |||
16 | Rayuwar injina | Lokaci | 20000 | |||
17 | Lokacin rufewa | ms | 75 | |||
18 | Lokacin budewa | ms | 60 | |||
19 | Lokacin ajiya a ƙarƙashin ƙimar ƙarfin lantarki | s | 10 |