Yanayin Aiki
Yanayin amfani na yau da kullun
a.Yanayin zafin jiki na yanayi, mafi ƙarancin -30 °, matsakaicin + 40 °;matsakaicin zafin jiki da aka auna a cikin sa'o'i 24 bai wuce 35 ° ba;
b.Tsayin bai wuce 1000m ba;
c.Matsayin gurɓataccen iska na kewaye ba zai wuce matakin II ba;
d.Iskar da ke kewaye ba a fili ta ƙazantar da ƙura, hayaki, iskar gas ko mai ƙonewa, tururi ko fesa gishiri;
e.Kauri na icing ba zai wuce 20mm ba;
f.Gudun iska bai wuce 34m/s ba;
g.Fissure seismic baya wuce digiri 8;
h.Yanayin zafi:
Matsakaicin ƙimar yanayin zafi da aka auna a cikin awanni 24, bai wuce 95% ba;
Matsakaicin ƙimar tururin ruwa da aka auna a cikin 24h bai wuce 2.2kPa ba;
Matsakaicin yanayin zafi na kowane wata baya wuce 90%;
Matsakaicin matsa lamba na ruwa na wata-wata baya wuce 1.8kPa;
Idan abubuwan da aka ambata na yau da kullun na amfani sun wuce, da fatan za a tuntuɓi masana'anta a gaba, kuma da fatan za a saka lokacin yin oda;
Yanayin amfani mara kyau
Ciki har da matsananciyar yanayin amfani kamar tsayi sama da mita 1000, saurin canjin zafin jiki, icing sama da 20mm, gurɓataccen gurɓataccen gurɓataccen ruwa, ƙazanta mai ƙarfi, mildew, yashi, ƙura, sanyi mai zafi, zafi mai zafi, girgiza, tasiri, lilo, da sauransu, don Allah a yi shawarwari a ciki gaba lokacin yin oda.
Babban Ma'aunin Fasaha Na samfuran Zw7 Series
A'a. | Bayani | Naúrar | Bayanai | ||
1 | Ƙarfin wutar lantarki | kV | 40.5 | ||
2 | 1 min Ƙididdigar mitar wutar lantarki ta jure ƙarfin lantarki 1min | kV | 95 | ||
3 | Ƙimar walƙiya mai ƙima ta jure ƙarfin lantarki | kV | 185 | ||
4 | Ƙididdigar mita | Hz | 50 | ||
5 | Ƙididdigar halin yanzu | A | 630, 1250, 1600, 2000, 2500 | ||
6 | Ƙididdigar ɗan gajeren lokaci jure halin yanzu | kA | 20 | 25 | 31.5 |
7 | Ƙimar kololuwar jure halin yanzu | 50 | 63 | 80 | |
8 | An ƙididdige ɗan gajeren da'ira karya halin yanzu | 20 | 25 | 31.5 | |
9 | An ƙididdige gajeriyar da'ira yin halin yanzu | 50 | 63 | 80 | |
10 | An ƙididdige ɗan gajeren lokaci | s | 4 | ||
11 | Bangaren DC na rated short-circuit break current |
| 51 | ||
12 | Ƙimar ƙimar wutar lantarki ta wucin gadi (TRV) | kV | 114 | ||
13 | Ƙimar wutar lantarki ta na'urorin rufewa da buɗewa da da'irori masu taimako | V | DC / AC 220V, DC / AC 110V | ||
14 | An ƙididdige jerin aiki |
| O-0.3s-CO-15s-CO | ||
15 | Lokacin budewa | ms | 20 zuwa 50 | ||
16 | Lokacin rufewa | 30 zuwa 80 | |||
17 | Tsawon lokacin DC na rated short-circuit break current | 45 | |||
18 | Ƙididdigar kebul na caji mai karye halin yanzu | A | 50 | ||
19 | Rayuwar sabis |
| E2-C2-M2 (10000) | ||
20 | An ƙididdige ɗan gajeren kewayawa lokacin karya na yanzu | Lokaci | 20 |
Teburin Daidaita Taro Na Samfuran Zw7
A'a. | Bayani | Naúrar | Bayanai |
1 | Nisan bude lamba | mm | 20± 2 |
2 | Tuntuɓi bugun jini | 4 ± 1 | |
3 | Matsakaicin saurin rufewa (auna lamba kafin rufewa zuwa 10mm kafin rufewa) | m/s | 0.8 ± 0.3 |
4 | Matsakaicin saurin buɗewa (ana raba lambar aunawa zuwa 10mm baya) | 1.6 ± 0.3 | |
5 | Lokacin billa na lamba rufe | ms | ≤5 |
6 | Lokacin billa na lamba rufe | ≤2 | |
7 | Buɗe lamba ta sandar sanda uku a lokuta daban-daban | ≤2 | |
8 | Babban juriya na kewaye na kowane sanda | μΩ | ≤100 (Ba tare da kayan aikin wuta ba) |
9 | Lura: Siffofin da ke sama suna nuni zuwa ƙimar ƙarfin aiki |
Girman Shigarwa
A tsayin mita 1000 (nisa ta tsakiya na 710mm), tsayin mita 2000 (nisa na tsakiya na 780), da tsayin mita 3000 (nisa na tsakiya na 850), gabaɗayan girma daga cikin na'urar kashe wayar kamar haka:
A tsayin mita 4000 (nisa ta tsakiya 920), a 5000 mita (tsakiyar nisa 1000) mita, da overall girma na na'urar hana zirga-zirga kamar haka: